3 timer styles available: single shot, accumulating, and accumulating with buzzer in 24, 120, and 230 volt A/C.

Add an “Aqua-Miser shower kit” which includes valve and transformer for shower applications.

TIMERS

Timers are available in 24, 120, and 230 volt A/C.
Single shot timers (part number ends in “SS”) can be set to accept from 1 to 7 coins/tokens to start. Timer runs for set time and then turns off. Customer must wait for time to expire before more coins can be added.
Accumulating timers can be set for 1 to 7 coins to start. Each additional coin, after initial set of coins, will add more time. As long as coins are added before time expires, time will continue to accumulate. (For example: If timer is set so that each coin is worth 1 minute, with 4 coins to start; customer must insert 4 coins to start timer, giving them 4 minutes. Each additional coin inserted before time expires, will add 1 additional minute.)
Optional output buzzers will sound when there is little time remaining, alerting the customer to either add more coins, or let time expire. 15 second increment timers have a 1 minute warning. 2 minute increment timers have a 2 minute warning.
15 second increment timers (part number contains “-1”) – each coin can only be worth an increment of 15 seconds. For example, a coin could be worth 15 seconds, 30 seconds, or 15 minutes 45 seconds etc.; up to 31 minutes 45 seconds.
2 minute increment timer (part number contains “-2”) – each coin can only be worth an increment of 2 minutes. For example, a coin can be worth 2, 4 or 36 minutes etc. up to 254 minutes, but not 5 minutes, as it is not an increment of 2.
Please click on the links below for instructions on how to set your timer or wiring instructions:
20-24V-1SS – 24 VOLT A/C, SINGLE SHOT, 15 SECOND INCREMENT
20-24V-2SS – 24 VOLT A/C, SINGLE SHOT, 2 MINUTE INCREMENT
20-24V-1 – 24 VOLT A/C, ACCUMULATING, 15 SECOND INCREMENT
20-24V-2 – 24 VOLT A/C, ACCUMULATING, 2 MINUTE INCREMENT
20-120V-1SS – 120 VOLT A/C, SINGLE SHOT, 15 SECOND INCREMENT
20-120V-2SS – 120 VOLT A/C, SINGLE SHOT, 2 MINUTE INCREMENT
20-120V-1 – 120 VOLT A/C, ACCUMULATING, 15 SECOND INCREMENT
20-120V-2 – 120 VOLT A/C, ACCUMULATING, 2 MINUTE INCREMENT
20-230V-1 – 230 VOLT A/C, ACCUMULATING, 15 SECOND INCREMENT
20-230V-2 – 230 VOLT A/C, ACCUMULATING, 2 MINUTE INCREMENT

** Some specialty timers available. Please call for details. **

COMPLETE SYSTEMS

System 1 – HM5 series meter case, Model 444 acceptor, single shot timer
System 2 – HM5 series meter case, Model 444 acceptor, accumulating timer
System 3 – HM5 series meter case, Vertical 8 acceptor, single shot timer
System 4 – HM5 series meter case, Vertical 8 acceptor, accumulating timer
System 5 – HM6 series meter case with black powder coat, drop coin acceptor, single shot timer
System 5 SS – HM6 series meter case with brushed stainless steel finish, drop coin acceptor, single shot timer
System 6 – HM6 series meter case with black powder coat, drop coin acceptor, accumulating timer
System 6 SS – HM6 series meter case with brushed stainless steel finish, drop coin acceptor, accumulating timer
System 7 – HM6 series meter case with black powder coat, drop coin acceptor, accumulating timer with output buzzer
System 7 SS – HM6 series meter case with brushed stainless steel finish, drop coin acceptor, accumulating timer with output buzzer
System 8 – push button meter with single shot timer
System 9 – push button meter with accumulating timer

Coins Slot With Digital Timer Countdown

System 10 – push button meter, accumulating timer with output buzzer

AQUA-MISER SHOWER KIT

Coins Slot With Digital Timer Stopwatch

The shower kit consists of an in-line valve and transformer and can be added to any System.

In-line valve is 3/8″ ID.
Right angle valve (3/8″ ID) available upon request. Additional charges may apply. Call for details.
There is quite a bit of hype about various “certifications” on shower equipment.
First, in most applications, UL/CSA listings are REQUIRED only on systems rated to operate at 36 Volts or more. Listings for lesser voltages is voluntary.
All of the components in Monarch meters are UL/CSA listed.
Any company offering such components can offer no more than that, as the quality of the installation will determine the true safety of the units.

Coins Slot With Digital Timer 20 Minutes

Secondly, There is no central clearing or certifying agency for ADA compliance. According to offices within the Federal and State Justice department who handle challenges under ADA, the greatest concern is with how the installation is made. For example, if the units are installed in areas inaccessible to those in wheelchairs, then there is no ADA compliance. No Manufacturer can claim to be fully ADA compliant unless the Manufacturer is also accepting responsibility for the installer.
Monarch has produced meters for use in showers and other coin metered applications since 1903.
There are units in service today that were originally sold with electro-mechanical timers in the 60’s, long before many thought that conserving water and minimizing waste in showers was of any interest at all. The recent addition of the HM6 and the accumulative timers, as well as the up coming introduction of an in-wall unit, demonstrate Monarch’s commitment to serving this need. Monarch units are in use in many countries as well as North American locations.